- • No, it is not possible. Setting the INTELLIPOWER 150 allows selecting the type of projector that will be connected (AWW or RGB), but this setting is only for all 32 outputs of INTELLIPOWER 150. Clearly, if a INTELLIPOWER 150 is set to control RGB projectors, RGB projectors only have to be connected. If the INTELLIPOWER 150 is set to order AWW projectors, then only AWW projectors will be connected. This is due to the currents required to control these LEDs projectors, depending on the nature of these LEDs (RGB or AWW). So if 2 types of projectors are used on a facility, they must be gathered by type on INTELLIPOWER 150 correctly set.
- No, the device is expected to drive from 1 to 3 projectors. It must just be remembered to leave in place the wire on the shunt or leaving the INTELLIPOWER 150 unused and do not forget to set up the plugs or skin tops with no projector if you want to install the INTELLIPOWER 150 outside.
- • How to do the setup of the unit?
The INTELLIPOWER 150 is provided with an internal panel. DMX Modes and DMX address of the system can be changed via the control panel, which requires to open the device to access it. It is also possible to use remote controller COUGAR 2 to make these adjustments. The advantage of this device is that it simply plug on the route of the DMX IN INTELLIPOWER 150, which can be useful if the INTELLIPOWER 150 is already installed and is not easily accessible.
- • Should we comply with the wiring system in star of INTELLIPOWER 150?
Absolutely, the rule is simple: 1 projector connected by output only.
In any case must wiring be made in series or parallel of multiple projectors on a single output of INTELLIPOWER 150.
- • The INTELLIPOWER 150 is provided with input / output DMX 512 and also input / output power sector. What is the maximum amount of INTELLIPOWER that can be connected in cascade?
The limit for wiring DMX is fixed by the standard DMX USITT 1990, or 32 receivers up on the same line DMX 512. As for power, a INTELLIPOWER 150 consumes 150Watts, and that part of its internal cables feeding limits the total current through them to 6 Amperes.
This corresponds to 10 INTELLIPOWER 150 connected in cascade arrangements 230/240 V AC, for a total power of 1500 Watts.
And if a sector 110 V AC, this sets the limit at 4 INTELLIPOWER 150 connected in cascade, a power of 600 Watts.
- • The control panel to drive the INTELLIPOWER 150 does not seem to respond, nothing happens. Is the INTELLIPOWER 150 down?
- The panel of the INTELLIPOWER 150 is in standby mode by default, which means that the display does nothing else than the presence of witnesses voltage (left of the display) and DMX presence (right of the display), and the buttons are inactive. To break this Mode, you must hide at the same time MODE and ENTER and then hide the UP and DOWN buttons. The display lights up and then shows the DMX of the device, and keys become active. You can then get in the device menu. Without action on these keys within a period of 10 seconds, the device automatically goes into Stand By mode.